Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros

Base de datos
Tópicos
Tipo del documento
Intervalo de año
1.
PLoS One ; 17(11): e0278089, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-2140685

RESUMEN

INTRODUCTION: Surgical tracheostomy (ST) and Percutaneous dilatational tracheostomy (PDT) are classified as high-risk aerosol-generating procedures and might lead to healthcare workers (HCW) infection. Albeit the COVID-19 strain slightly released since the vaccination era, preventing HCW from infection remains a major economical and medical concern. To date, there is no study monitoring particle emissions during ST and PDT in a clinical setting. The aim of this study was to monitor particle emissions during ST and PDT in a swine model. METHODS: A randomized animal study on swine model with induced acute respiratory distress syndrome (ARDS) was conducted. A dedicated room with controlled airflow was used to standardize the measurements obtained using an airborne optical particle counter. 6 ST and 6 PDT were performed in 12 pigs. Airborne particles (diameter of 0.5 to 3 µm) were continuously measured; video and audio data were recorded. The emission of particles was considered as significant if the number of particles increased beyond the normal variations of baseline particle contamination determinations in the room. These significant emissions were interpreted in the light of video and audio recordings. Duration of procedures, number of expiratory pauses, technical errors and adverse events were also analyzed. RESULTS: 10 procedures (5 ST and 5 PDT) were fully analyzable. There was no systematic aerosolization during procedures. However, in 1/5 ST and 4/5 PDT, minor leaks and some adverse events (cuff perforation in 1 ST and 1 PDT) occurred. Human factors were responsible for 1 aerosolization during 1 PDT procedure. ST duration was significantly shorter than PDT (8.6 ± 1.3 vs 15.6 ± 1.9 minutes) and required less expiratory pauses (1 vs 6.8 ± 1.2). CONCLUSIONS: COVID-19 adaptations allow preventing for major aerosol leaks for both ST and PDT, contributing to preserving healthcare workers during COVID-19 outbreak, but failed to achieve a perfectly airtight procedure. However, with COVID-19 adaptations, PDT required more expiratory pauses and more time than ST. Human factors and adverse events may lead to aerosolization and might be more frequent in PDT.


Asunto(s)
COVID-19 , Traqueostomía , Humanos , Porcinos , Animales , Traqueostomía/efectos adversos , Traqueostomía/métodos , Dilatación/métodos , Procedimientos Quirúrgicos Vasculares
2.
Front Med (Lausanne) ; 9: 883950, 2022.
Artículo en Inglés | MEDLINE | ID: covidwho-1872087

RESUMEN

Background: The current standard of care during severe acute respiratory distress syndrome (ARDS) is based on low tidal volume (VT) ventilation, at 6 mL/kg of predicted body weight. The time-controlled adaptive ventilation (TCAV) is an alternative strategy, based on specific settings of the airway pressure release ventilation (APRV) mode. Briefly, TCAV reduces lung injury, including: (1) an improvement in alveolar recruitment and homogeneity; (2) reduction in alveolar and alveolar duct micro-strain and stress-risers. TCAV can result in higher intra-thoracic pressures and thus impair hemodynamics resulting from heart-lung interactions. The objective of our study was to compare hemodynamics between TCAV and conventional protective ventilation in a porcine ARDS model. Methods: In 10 pigs (63-73 kg), lung injury was induced by repeated bronchial saline lavages followed by 2 h of injurious ventilation. The animals were then randomized into two groups: (1) Conventional protective ventilation with a VT of 6 mL/kg and PEEP adjusted to a plateau pressure set between 28 and 30 cmH2O; (2) TCAV group with P-high set between 27 and 29 cmH2O, P-low at 0 cmH2O, T-low adjusted to terminate at 75% of the expiratory flow peak, and T-high at 3-4 s, with I:E > 6:1. Results: Both lung elastance and PaO2:FiO2 were consistent with severe ARDS after 2 h of injurious mechanical ventilation. There was no significant difference in systemic arterial blood pressure, pulmonary blood pressure or cardiac output between Conventional protective ventilation and TCAV. Levels of total PEEP were significantly higher in the TCAV group (p < 0.05). Driving pressure and lung elastance were significantly lower in the TCAV group (p < 0.05). Conclusion: No hemodynamic adverse events were observed in the TCAV group compared as to the standard protective ventilation group in this swine ARDS model, and TCAV appeared to be beneficial to the respiratory system.

3.
Pharmaceutics ; 14(5)2022 Apr 30.
Artículo en Inglés | MEDLINE | ID: covidwho-1875732

RESUMEN

BACKGROUND: Adjusting drug therapy under veno-venous extracorporeal membrane oxygenation (VV ECMO) is challenging. Although impaired pharmacokinetics (PK) under VV ECMO have been reported for sedative drugs and antibiotics, data about amiodarone are lacking. We evaluated the pharmacokinetics of amiodarone under VV ECMO both in vitro and in vivo. METHODS: In vitro: Amiodarone concentration decays were compared between closed-loop ECMO and control stirring containers over a 24 h period. In vivo: Potassium-induced cardiac arrest in 10 pigs with ARDS, assigned to either control or VV ECMO groups, was treated with 300 mg amiodarone injection under continuous cardiopulmonary resuscitation. Pharmacokinetic parameters Cmax, Tmax AUC and F were determined from both direct amiodarone plasma concentrations observation and non-linear mixed effects modeling estimation. RESULTS: An in vitro study revealed a rapid and significant decrease in amiodarone concentrations in the closed-loop ECMO circuitry whereas it remained stable in control experiment. In vivo study revealed a 32% decrease in the AUC and a significant 42% drop of Cmax in the VV ECMO group as compared to controls. No difference in Tmax was observed. VV ECMO significantly modified both central distribution volume and amiodarone clearance. Monte Carlo simulations predicted that a 600 mg bolus of amiodarone under VV ECMO would achieve the amiodarone bioavailability observed in the control group. CONCLUSIONS: This is the first study to report decreased amiodarone bioavailability under VV ECMO. Higher doses of amiodarone should be considered for effective amiodarone exposure under VV ECMO.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA